FLEX RLTF 21 GRAY W/3176 NUT

[3479]

For Flexible Cords. PG HUBS - For use in clearance or threaded holes. For a wider range of materials, cable sizes, and threads see page 1-10 Heyco-Tite Cordgrips
Foreign Patents
  • Ten sizes for cable, diameters ranging from .064 (1.6 mm) to .709" (18.0 mm).
  • We recommend using the fitting with the smallest maximum diameter that will fit your application.
  • Acme threads on body prevent skipping and speed installation. All nylon construction with TPE gland resists salt water, weak acids, gasoline, alcohol, oil, grease, and common solvents. This feature is not assessed by UL certification or testing.
  • Flexible “Pigtail” extender prevents sharp bends and extends cable life. PG hub threads are steel conduit threads per DIN 40430.
  • Working temperatures : -22&176;F (-30&176;C) to 212&176;F (100&176;C).
  • Protection class IP 68 per DIN 40050.
  • Suitable for NEMA type 4 and 6 enclosures.
  • Locknuts are included. For nylon or steel locknut specifications or to order locknuts separately.
Listed Under Underwriters’ Laboratories."
Specifications
Color Gray
Description FLEX RLTF 21
Min. Dia. [inches] 0.25
Min. Dia. [mm] 6.4
Max. Dia. [inches] 0.485
Max. Dia. [mm] 12.3
Clearance Hole - A [inches] 1.115
Clearance Hole - A [mm] 28.3
Max. O. A. Length - B [inches] 5.03
Max. O. A. Length - B [mm] 127.8
Thread Length - C [inches] 0.52
Thread Length - C [mm] 13.2
Wrenching Nut Thk. - D [inches] 0.23
Wrenching Nut Thk. - D [mm] 5.8
Wrenching Flats - E [mm] 33
Material Polyamide 6/6 Nylon w/TPE Gland
Certifications Listed under Underwriters' Laboratories File #E-51579
Recogni
Flammability Rating 94V-2 Standard
Temp. Rating -22ºF (30ºC) to 212ºF (100ºC)
IP Rating IP 68 per DIN 40050
217.53
Quantity:
Join Our Email List
Email:  
SafeSubscribe Label

Our website uses cookies. For more information on our cookie use, see our Privacy Policy. By continuing to use this website you agree to our use of these cookies.